STL200STL200HBSTEALTHSpecifications:Switching Capacity: 8 ampsVoltage: 120 volts1000 watts Incandescent500 watts FluorescentDetection Pattern: 50’
1. Check that lamps and fixtures work. Compare wiring to the wiring diagram in this manual. Check that the power is on.2. If installing during dayligh
1. Check that the sensor is level from side to side and pointed at the area you desire. If unit is tilted, part of the detection zone may be high in t
1. Lights may turn on occasionallyduring rain, snow and windstorms because the sensor is detection changes in temperature.Solution:Mount sensor in pro
Your Stealth will be replaced or repaired, at our option, if it proves to be defective in workmanship or materials within ten years from the date of o
Contents of Accessory Kit• 2 Lens Masks• Indoor Switchplate Label• 3 Wire Nuts• Crossbar with Green Ground Screw • Hanging Hook• 1/2" Close Up Pl
MAKESITEASY!Toll Free Phone Toll Free Fax Fax on Demand Call our friendly experts. Send faxes to RAB Faxed information,8AM - 6PM ET Mon. - Fri.
TURN OFF ALL POWER AT CIRCUIT BREAKER /FUSE PANEL.• Read entire Installation Manual before proceeding.• All wiring should comply with local electri
How Does the STEALTH Work?Stealth’s infrared sensor “sees” small temperature changes caused by the motion of people or cars within its protection zone
• Choose a location from which the sensor can “see” all the paths of movement.• The sensor may be wall or ceiling mounted.• As distance from the s
1. Attach the Universal Mounting bar with the bar screws (provid-ed) to the junction box. If you are attaching your STL200 kit to a surface mount wea
5Basic Wiring DiagramBasic Kit WiringSwitchplate LabelMultiple fixtures may be wired to a single sensor.To handle loads greater than 1,000 watts, a qu
Aiming And Walk Testing Walk TestThe purpose of the Walk Test is to check and adjust the coverage pattern. Stealth has a 5 minute Test Period which a
1. Make sure that the sensor is not in Manual Override Mode. Turn power OFF for 10 seconds, then ON Sensor will be in Test Mode for approximately 5 mi
Technical Tips:Lights Turn On and Off Inappropriately1. Make sure the sensor is installed on its own dedicated circuit, free of motor loads such as HV
Commentaires sur ces manuels